Technical parameters

COMBAS fragment-separator main ion-optical parameters

 Bρmax  4,5     [T m]    
 Solid angle (maximum)  6,4     [mcr]
 Momentum acceptance (maximum)  20[%]
 Horizontal magnification in Fd  -0,36
 Vertical magnification in Fd  -6,0 [%]
 Momentum dispersion (in the linear approximation)  1,53 [cm/%]a
 Momentum resolution  4360[FWHM]b
 Horizontal magnification in Fa  1
 Vertical magnification in Fa  1
 Full length of the channel  14,5 [cm] from F0 to Fa

a In case the second- and third-order aberrations are taken into consideration 20% momentum capture dispersion function is described by the following equation: 
X=1,53δ – 0,03δ2, where δ=Δp/p0.

b Main object slit width = 1 mm. Second- and third- order aberrations are taken into consideration.

MAGNET PARAMETERS

 Parameters M1, M8    
M2, M7   
M3, M6  
M4, M5    
 Central path induction, Bmax, [T] 1,125 1,125 1,5 1,5
 Central path induction, Bnominal, [T] 0,875   
0,875   
1,167     
1,167   
 Central path radius, ρ[m]  4 4 3  3
 Central path pole gap, h [cm] 12   
 10 
 6  
 6    
 Effective working area width[cm]  40  80  60  50
 Deviation 250   
250    
7,50  
7,50